Example:
Dynamic, software-controlled temperature test for motor-operated opening mechanism for Mars probe with a 35 kg load from - 75°C bis + 150°C.
The large chamber observation window enabled the
test object's sequences of movements to be recorded
continuously using a video camera. The motors'
current consumption and other parameters were
documented at the same time.